HAND HELD PRESSURE SENSOR FOR SMS TENSIOMETERS - SMS 2500S

Click on the pictures below to zoom (not available for all pictues on this website).



Setting the ref. pressure back to zero
Setting the ref. pressure back to zero


Display before the measurement
Display before the measurement


Carrying bag to protect the SMS 2500S
Carrying bag to protect the SMS 2500S


Use on the SMS tensiometer (order separately)
Use on the SMS tensiometer (order separately)


Use on the Tensionic tensiometer (order separately)
Use on the Tensionic tensiometer (order separately)
Home
September 4, 2010

TENSIOMETERS 

Standard tensiometers manual reading
With mercury manometer STM 2150 series
With 'Bourdon' manometer SR 1000 series
With SMS 2500S hand held meter on SMS 2000 tubes
Simple tensiometer tube SMS 2000 series

Standard tensiometers electronic output

Tensiometers for specific apps (lab, greenhouse,...)

Accessories (syringe, stoppers, ...)





Other views


What do I measure ?

The total soil water suction in the tensiometer tube (also known as soil water potential or hydraulic charge)

APPLICATIONS
AGRICULTURE
Precise management of irrigations.
Management of adjusted water stress levels for seed production.

AGRONOMY, ENVT

Studies on water bulbs in soils.
Water stress management for modeling.
Checking water potential levels before starting a soil solution sampling campaign.
Following water percolation periods.

HYDROLOGY

Water potential measurements in unsaturated soils.
Soil water caracteristic curves.
Studies on water flows : percolation...
Studies on water ressources : refilling of the water tablemonitoring.
Water balance.

SOIL PHYSICS

Analysis of water tranfers, water potential measurements.

HAND HELD PRESSURE SENSOR FOR SMS TENSIOMETERS - SMS 2500S


The measuring technique with the SMS 2500S electronic pressure meter consists in piercing through a silicon bung closing a tensiometer, by means of a hypodermic needle, itself connected to a pressure transducer (or vacuumeter). This type of measure, both very precise and very economical (a unique appliance can be used on a great number of tensiometers) is particularly practical for all users of tensiometric technics in general. This appliance is easily transportable in its small bag and will allow the user to envisage all field experimentations more or less far from the laboratory. It is obvious to use such a system in agronomy or agriculture for managing water use : determination of irrigation conditions, of the amount of water needed and of the best moment to irrigate. The knowledge of water potentials is also very important when a control of groundwater ressources must be done.

The measuring principle of this system is both simple and gives very accurate readings. It consists in measuring the vacuum created in an airtight system filled with water which equilibrates with the soil through the porous ceramic.

The porous ceramic cup is glued to the bottom of a hollow PVC tube which will be set into the soil to measure its water potential. The water saturated ceramic will be linked to the plastic tube full of water (sort of water container) which is also linked by a capillary to a mercury reservoir.

Key Advantages

ACCURATE
EASY TO USE
ECONOMIC (one sensor can be used on a great number of SMS tensiometers)

Disadvantages
No monitoring

TECHNICAL CHARACTERISTICS

Measuring range : 0 Hpa à -999 Hpa.

Accuracy : < 2% of full scale.

Pressure sensor : Differential piezzo-resistive sensor

Null Offset : adjustable by user.

Calibration : a calibration certificate is supplied with each device.

Measurement : by hypodermic needle fixed in a DELRIN cylinder. This cylinder is adapted to all standard tensiometric tubes . (21,5 mm < Ø < 23 mm).

Works also : for the combined tensiometer & lysimeter, ref. Tensionic.

Display : by LCD display. Direct readings of the measured value in Hpa (or mbar).

Power : dry cell 9 Volts 6LR61 or PP23 type.

Autonomy : more than 3 years (when using press-button) / less than a week if the device is left on / a year and a half if both switches are used.

Electrical protection : electronic system against reversal polarity.

Warning signal for low batteries (on LCD display).

Temperature compensated : from 0°C to + 50°C.

Disturbance due to the air volume contained in the sensor : < to 5 Hpa for an air height equal to 20mm .< 10 Hpa if the air level is equal to 10mm.

Dimensions : 145 x 80 x 117 mm

Weight : 185 grammes.

Operating temperature : - 5°C to + 50°C

Storage temperature : -10°C to + 60°C

Waterproof : WARNING , this equipment is not waterproof.

 

 

 

 

 

 

 

 


Download brochure
Download brochure

Pressure sensor (hand held) for SMS tensiometers
Tensiometry - comparison between techniques

Ask for a quotation
SMS 2500S Qty 
Auger STM 21600 
SMS tensiometer tubes :
Length (install. + 10cm)  Qty 
Tensionic tubes :
Length (install. + 25cm)  Qty 
Qty 



The standard set

The SMS 2500S is delivered with 9V battery, two hypodermic needles and a carrying bag. It is ready to use.

The tensiometer tubes, ref. SMS 2000 or Tensionic model must be ordered separately.

You also need
. Tensiometer tubes which must be placed into the soil, ref. SMS 2000 or the combined tensiometer &
lysimeter, ref. Tensionic, or
microtensiometers with flexible tubes, ref. SMS 2000S
. An auger to place the tubes into the soil, ref. STM 21600



SDEC France
Z.I de la Gare
 BP 27 Reignac sur Indre
37310 Tauxigny
France
Ph : +33 2 4794 1000
Fax : +33 2 4794 1713
e-mail : click here